日本富士温控仪PXR5NAY1-8W000-C
pxw5,pxw7,pxw9型号已淘汰,对应的替代产品为pxr5,pxr7,pxr9。
pxr系列温控器简介:
◆双排显示pv、sv等数据;
◆多种热电偶信号、热电阻信号、线形信号输入;
◆带手/自动模式,切换便利;
◆8段斜坡/保温程序(选件)
◆满量程0.5%精度,85-256v ac 50/60hz供电工作。
◆再传输输出功能dc4-20ma和rs485通讯功能(选件)
◆遥控输入功能(选件)
◆数字量输入Zui多2点(选件):通过一点开关量on/off,可改变设定值sv,控制动作起/停,斜坡/保温控制的开始/复位,自动调节功能的起/停,报警锁存的复位、定时器计时开始;
◆二路输出(选件):用于加热/冷却控制
◆加热断线报警(选件)
◆自带一路报警功能:Zui多3点(选件)。
富士温控表pxr4/5/7/9系列选型说明
数字位
|
规格
面板尺寸w×h
|
代号
|
||||||||||
4
|
5
|
6
|
7
|
8
|
-
|
9
|
10
|
11
|
12
|
13
|
||
4
|
48×48mm
|
4
|
|
|
|
|
|
|
|
|
|
|
48×96mm
|
5
|
|
|
|
|
|
|
|
|
|
|
|
72×72mm
|
7
|
|
|
|
|
|
|
|
|
|
|
|
96×96mm
|
9
|
|
|
|
|
|
|
|
|
|
|
|
5
|
输入信号
|
|
|
|
|
|
|
|
|
|
|
|
热电偶(℃)
|
|
t
|
|
|
|
|
|
|
|
|
|
|
热电偶(℉)
|
|
r
|
|
|
|
|
|
|
|
|
|
|
rtd/pt100欧姆(℃)
|
|
n
|
|
|
|
|
|
|
|
|
|
|
rtd/pt100欧姆(℉。)
|
|
s
|
|
|
|
|
|
|
|
|
|
|
1~5v dc
|
|
a
|
|
|
|
|
|
|
|
|
|
|
4~20ma dc
|
|
b
|
|
|
|
|
|
|
|
|
|
|
6
|
控制输出1
|
|
|
|
|
|
|
|
|
|
|
|
继电器接点输出
|
|
|
a
|
|
|
|
|
|
|
|
|
|
ssr/ssc驱动输出
|
|
|
c
|
|
|
|
|
|
|
|
|
|
4~20ma dc输出 注1
|
|
|
e
|
|
|
|
|
|
|
|
|
|
7
|
控制输出2
|
|
|
|
|
|
|
|
|
|
|
|
无
|
|
|
|
y
|
|
|
|
|
|
|
|
|
继电器接点输出
|
|
|
|
a
|
|
|
|
|
|
|
|
|
ssr/ssc驱动输出
|
|
|
|
c
|
|
|
|
|
|
|
|
|
4~20ma dc输出
|
|
|
|
e
|
|
|
|
|
|
|
|
|
再传输输出(4~20ma dc)
|
|
|
|
r
|
|
|
|
|
|
|
|
|
8
|
版本号
|
|
|
|
|
1
|
-
|
|
|
|
|
|
9.
|
附加功能1
|
|
|
|
|
|
|
|
|
|
|
|
无报警
|
|
|
|
|
|
|
0
|
|
|
|
|
|
1个报警
|
|
|
|
|
|
|
8
|
|
|
|
|
|
加热器断路报警 注2
|
|
|
|
|
|
|
2
|
|
|
|
|
|
1个报警+加热器断路报警 注2
|
|
|
|
|
|
|
3
|
|
|
|
|
|
8段斜坡/保温程序
|
|
|
|
|
|
|
4
|
|
|
|
|
|
1个报警+8段斜坡/保温程序
|
|
|
|
|
|
|
5
|
|
|
|
|
|
加热器断路报警+8段斜坡/保温程序 注2
|
|
|
|
|
|
|
6
|
|
|
|
|
|
1个报警+加热断路报警+8段斜坡/保温程序 注2
|
|
|
|
|
|
|
7
|
|
|
|
|
|
两个报警
|
|
|
|
|
|
|
f
|
|
|
|
|
|
两个报警+8段斜坡/保温
|
|
|
|
|
|
|
g
|
|
|
|
|
|
两个报警+加热器断路报警+8段斜坡/保温 注2
|
|
|
|
|
|
|
h
|
|
|
|
|
|
3个报警
|
|
|
|
|
|
|
m
|
|
|
|
|
|
遥控设定 注2
|
|
|
|
|
|
|
d
|
|
|
|
|
|
遥控设定+2个报警 注2
|
|
|
|
|
|
|
p
|
|
|
|
|
|
10
|
操作说明书 电源电压
|
|
|
|
|
|
|
|
|
|
|
|
中文 100~240vac
|
|
|
|
|
|
|
|
w
|
|
|
|
|
日文 100~240vac
|
|
|
|
|
|
|
|
y
|
|
|
|
|
英文 100~240vac
|
|
|
|
|
|
|
|
v
|
|
|
|
|
无 24vac/24dc
|
|
|
|
|
|
|
|
c
|
|
|
|
|
日文 24vac/24dc
|
|
|
|
|
|
|
|
a
|
|
|
|
|
英文 24vac/24dc
|
|
|
|
|
|
|
|
b
|
|
|
|
|
11
12
13
|
附加功能2
|
|
|
|
|
|
|
|
|
|
|
|
无
|
|
|
|
|
|
|
|
|
0
|
0
|
0
|
|
rs485(modbus)通讯
|
|
|
|
|
|
|
|
|
m
|
0
|
0
|
|
rs485(z-asc11)通讯
|
|
|
|
|
|
|
|
|
n
|
0
|
0
|
|
1点数字输入
|
|
|
|
|
|
|
|
|
s
|
0
|
0
|
|
2点数字输入 注3
|
|
|
|
|
|
|
|
|
t
|
0
|
0
|
|
rs485(modbus)通讯+1点数字输入
|
|
|
|
|
|
|
|
|
v
|
0
|
0
|
|
rs485(z-asc11)通讯+1点数字输入
|
|
|
|
|
|
|
|
|
w
|
0
|
0
|
|
注1:输出4-20ma不能与加热器断路报警一起选。(即选项9中的2、3、6、7、h)
|
||||||||||||
注3:若选择2点数字输入,输出2或加热器断路报警不能选。
|
||||||||||||
注2:不能与rs485+1点数字输入一起选。(即选项11、12、13中的v00)
|